CJDDX - CALCIUM CHLORIDE DIHYDRATE

  • MSDS: CJDDX
  • Manufacturer: J T BAKER COMPANY
  • Product Name: CALCIUM CHLORIDE DIHYDRATE
  • National Stock Number: 6810-00-247-0601
Product Identification

Product ID:CALCIUM CHLORIDE DIHYDRATE
MSDS Date:12/08/1996
FSC:6810
NIIN:00-247-0601
Status Code:A
MSDS Number: CJDDX

Responsible Party
J.T. BAKER COMPANY
222 RED SCHOOL LANE
PHILLIPSBURG, NJ 08865-2219
US

Emergency Phone: 908-359-2151

Preparer: STRATEGIC SERVICES DIVISI

Cage: 70829

Contractor
PHOENIX INDUSTRIES INC
RICHMOND, VA 23222 US

Telephone: 264-5535

Cage: 0YED2

Ingredients

CALCIUM CHLORIDE

CAS: 10043-52-4

RTECS: EV9800000

Hazards

LD50 LC50 Mixture:LD50 (ORAL, RAT) 1,000 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS: EYES, SKIN, RESPIRATORY
& GI TRACTS. ACUTE- MAY CAUSE SEVERE EYE IRRITATION OR EVEN BURNS
FROM HEAT OF HYDROLYSIS. SOLID MAY CAUSE MILD SKIN IRRITATION;
STRONG SOLUTIONS OR SOLID IN CO NTACT WITH MOIST MAY CAUSE SEVERE
IRRITATION, EVEN BURNS. LOW TOXICITY MATERIAL BUT INGESTION MAY
CAUSE SERIOUS IRRITATION OF THE MUCOUS MEMBRANE DUE TO HEAT OF
HYDROLYSIS. LARGE AMOUNTS CAN CAUSE GA STROINTESTINAL UPSET,
VOMITING, ABDOMINAL PAIN. INHALATION OF GRANULAR MATERIAL DOES NOT
POSE A SIGNIFICANT INHALATION HAZARD, BUT INHALATION OF DUST MAY
CAUSE IRRITATION TO THE RESPIRATORY TRACT. CHR ONIC- UNKNOWN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:COUGHING, SHORTNESS OF BREATH, VOMITING,
ABDOMINAL PAIN, SEVERE IRRITATION, BURNS, PAIN

First Aid

First Aid:OBTAIN MEDICAL ATTENTION. INHALED: MOVE TO VENTILATED AREA.
IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS
DIFFICULT, GIVE OXYGEN. EYES: WASH WITH COPIOUS QUANTITIES OF
WATER FOR 15 M INUTES. SKIN: REMOVE EXCESS. FLUSH SKIN WITH LARGE
AMOUNT OF RUNNING WATER FOR 15 MINUTES. INGESTION: WASH OUT MOUTH
WITH RUNNING WATER. INDUCE VOMITING IMMEDIATELY AS DIRECTED BY
MEDICAL PERSONNEL. N EVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS
PERSON.

Fire Fighting

Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:NONE
Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:IN THE EVENT OF A FIRE, WEAR FULL PROTECTIVE
CLOTHING AND NIOSH-APPROVED SELF-CONTAINED BREATHING APPARATUS WITH
FULL FACEPIECE OPERATED IN POSITIVE PRESSURE MODE.
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE AN EXPLOSION HAZARD.

Accidental Release

Spill Release Procedures:VENTILATE AREA OF LEAK OR SPILL. WEAR
APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT AS SPECIFIED IN SECTION 8
(EXPOSURE CONTROL/PERSONAL PROTECTION). SWEEP UP AND CONTAINERIZE
FOR RECLAMATION OR DISPOSAL . VACUUMING OR WET SWEEPING MAY BE
AVOID DUST DISPERSAL. SMALL AMOUNTS OF RESIDUE MAY BE FLUSHED TO
SEWER WITH PLENTY OF WATER.

Handling

Handling and Storage Precautions:KEEP IN A TIGHTLY CLOSED CONTAINER,
STORED IN A COOL, DRY, VENTILATED AREA. PROTECT AGAINST PHYSICAL
DAMAGE. MOIST CALCIUM CHLORIDE AND CONCENTRATED SOLUTIONS CAN
CORRODE STEEL WHEN EXPOSED TO THE ATM OSPHERE, CALCIUM CHLORIDE
WILL ABSORB WATER AND FORM A SOLUTION. SEE OTHER PRECAUTIONS.
Other Precautions:DISPOSE OF CONTAINER AND UNUSED CONTENTS IN
ACCORDANCE WITH FEDERAL, STATE AND LOCAL REQUIREMENTS. CONTAINERS
OF THIS MATERIAL MAY BE HAZARDOUS WHEN EMPTY SINCE THEY RETAIN
PRODUCT RESIUDES (DUST, SOL IDS); OBSERVE ALL WARNINGS AND
PRECAUTIONS LISTED FOR THE PRODUCT.

Exposure Controls

Respiratory Protection:NIOSH APPROVED: FOR CONDITIONS OF USE WHERE
EXPOSURE TO THE DUST OR MIST IS APPARENT, A HALF-FACE DUST/MIST
RESPIRATOR MAY BE WORN. FOR EMERGENCIES OR INSTANCES WHERE THE
EXPOSURE LEVELS ARE NOT KNOWN , USE A FULL-FACE POSITIVE-PRESSURE,
AIR-SUPPLIED RESPIRATOR. WARNING: AIR-PURIFYING RESPIRAORS DO NOT
PROTECT WORKERS IN OXYGEN-DEFICIENT ATMOSPHERES.
Ventilation:A SYSTEM OF LOCAL AND/OR GENERAL EXHAUST IS RECOMMENDED TO
KEEP EMPLOYEE EXPOSURES AS LOW AS POSSIBLE. LOCAL EXHAUST
VENTILATION IS GENERALLY (SEE SUPPL.)
Protective Gloves:WEAR PROTECTIVE GLOVES AND CLEAN BODY-COVERING
CLOTHING.
Eye Protection:USE CHEMICAL SAFETY GOGGLES AND/OR FULL FACE SHIELD
WHERE DUSTING OR SPLASING
Other Protective Equipment:MAINTAIN GOOD HOUSEKEEPING IN WORK AREA.
DUST DEPOSITS ON FLOORS AND OTHER SURFACES MAY PICK UP MOISTURE AND
CAUSE THE SURFACES TO BECOME SLIPPERY AND PRESENT SAFETY HAZARDS.
Supplemental Safety and Health
LOCAL EXHAUST VENTILATION IS GENERALLY PREFERRED BECAUSE IT CAN CONTROL
THE EMISSION OF THE CONTAMINANT AT ITS SOURCE, PREVENTING
DISPERSION OF IT INTO THE GENERAL WORK AREA.

Chemical Properties

HCC:B3
Boiling Pt:>1600.C, 2912.F
Melt/Freeze Pt:=260.C, 500.F
M.P/F.P Text:APPROX.
pH:8-9 AQUEOUS SOL
Solubility in Water:FREELY SOLUBLE IN WATER
Appearance and Odor:ODORLESS, COARSE WHITE POWDER OR MIXTURE OF COARSE
WHITE POWDER AND MEDIUM SIZ
Percent Volatiles by Volume:@ 21C 0

Stability

Stability Indicator/Materials to Avoid:YES
METHYL VINYL ETHER, WATER, ZINC, BROMINE, TRIFLUORIDE, MIXTURE OF LIME
AND BORIC ACID, BARIUM CHLORIDE, AND 2-FURAN PERCARBOXYLIC ACID.
METALS WILL SLOWLY CORRODE IN AQUEOUS CALCIUM CHLORIDE SOLUTIONS.
AL (AND ALLOYS) AND Y
Stability Condition to Avoid:INCOMPATIBILITIES. STABLE UNDER CONDITIONS
OF USE AND STORAGE. SUBSTANCES WILL PICK UP MOISTURE FROM THE AIR
AND GO INTO SOLUTION IF EXPOSED IN OPEN CONTAINERS.
Hazardous Decomposition Products:EMITS TOXIC CHLORINE FUMES WHEN HEATED
TO DECOMPOSITION. MAY FORM HYDROGEN CHLORIDE IN PRESENCE OF
SULFURIC OR PHOSPHORIC ACID OR WITH WATER AT ELEVATED TEMPERATURES.

Disposal

Waste Disposal Methods:WHATEVER CANNOT BE SAVED FOR RECOVERY OR
RECYCLING SHOULD BE MANAGED IN AN APPROPRIATE AND APPROVED WASTE
DISPOSAL FACILITY. PROCESSING USE OR CONTAMIANTION OF THIS PRODUCT
MAY CHANGE THE WASTE MANAGE MENT OPTIONS. STATE AND LOCAL DISPOSAL
REGULATIONS MAY DIFFER FROM FEDERAL DISPOSAL REGULATIONS. SEE
OTHER PRECAUTIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

Toxicology

Toxicological Information:FOR CALCIUM CHLORIDE ANHYDROUS: ORAL RAT
LD50: 1000 MG/KG; INVESTIGATED AS A MUTAGEN, TUMORIGEN.

Ecology

Ecological:ENVIRONMENTAL FATE: BASED ON AVAILABLE INFORMATION FOR
CALCIUM CHLORIDE ANHYDROUS, THIS MATERIAL WILL NOT BIODEGRADE OR
BIOACCUMULATE. ENVIRONMENTAL TOXICITY: BASED ON DATA FOR CALCIUM
CHLORIDE ANHYDR OUS, THE LC50/96-HOUR VALUES FOR FISH ARE OVER 100
MG/L.